TECHNICAL SPECIFICATIONS:
- The housing is durable sheet metal with a polyester powder coat finish.
- Rugged oversize (3-1/2" diameter) roller with S.S. ball bearings for smooth response.
- The unit is mounted on the bucket elevator by drilling (6) 1/4" diameter holes and a small cut-out.
- Typically used in pairs to provide protection to both sides of the elevator leg.
- General purpose (weatherproof) units and explosion proof units have (1) 3/4" NPT conduit opening.
- The units have a dry, unpowered micro switch rated for 10A @ 120 VAC, 240 VAC, and 480 VAC.
- The operating temperature range is -40ºF (-40ºC) to 150ºF (65ºC).
- The general-purpose units are rated NEMA 4/5 weatherproof and dust-tight, and explosionproof units are rated NEMA 7/9 for dust ignitionproof and vapor explosion proof.