TECHNICAL SPECIFICATIONS:
- The housing is cast aluminum, with optional epoxy or polyester powder coatings available. These coatings will provide protection against corrosion that is equal or greater than cast iron.
- The unit can be actuated via a cable pull from either or both directions on every unit; in other words, the unit is "double ended".
- The unit is mounted on the conveyor by drilling (3) 13/32" diameter holes.
- General purpose (weatherproof) units have (3) 3/4" NPT conduit openings.
- Explosionproof units have (1) 3/4" NPT conduit opening.
- The standard units have dry, unpowered SP/DT microswitch(es) rated for 20A @ 120 VAC, 240VAC, and 480 VAC; 1/2 amp at 125 VDC and 1/4 amp at 250 VDC.
- Special spring tensioning kits included with each RSB unit provide stability due to temperature fluctuations, and ease of cable adjustment.
- The operating temperature range is -40ºF (-40ºC) to 150ºF (65ºC).
- The general purpose units are rated NEMA 4/4X weatherproof and corrosion-resistant. Explosionproof units are rated NEMA 7/9 for dust ignition proof and vapor explosion proof. The dual-rated "D" units are rated NEMA 4 weatherproof and NEMA 9 dust ignition proof.
- The general purpose controls are IP65 compliant.
- All RSB models are UL listed except RSB-3, RSB-7 and RSB-8.
- Models RSB-1, RSB-2, RSB-2L, RSB-4, RSB-4L, RSB-5 and RSB-5L are CSA certified.
- Models RSB-1X, RSB-2X, RSB-4X and RSB-5X are CSA certified.
ADDITIONAL RESOURCES:
|