TECHNICAL SPECIFICATIONS:
- The housing is cast aluminum, with optional epoxy or polyester coatings available. These coatings will provide protection against corrosion that is equal or greater than cast iron.
- The unit can be connected to rotating equipment by means of a stub shaft and flexible coupling.
- The unit is mounted on the conveyor by drilling (4) 5/16" diameter holes.
- General purpose (weatherproof) units and explosionproof units have (2) 3/4" NPT conduit openings.
- The standard unit has 120 VAC power input (120 VAC transformer). Optional 240 VAC power input (240 VAC transformer) and 24V AC/DC (transformer-less) available upon request.
- The unit has a dry, unpowered DP/DT relay rated for 3A @ 120 VAC, 240 VAC, and 480 VAC.
- The unit is bi-directional, it will detect motion or loss of motion in either direction.
- The operating temperature range is -50ºF to 150ºF (-45ºC to 66ºC).
- Standard unit has a 12 segment encoder disk. Special 50 segment encoder disk is available upon request for low speed applications (5 RPM or slower).
- The general purpose units are rated NEMA 4/4X weatherproof and corrosion-resistant, and explosion proof units are rated NEMA 7/9 for vapor explosion proof and dust ignition proof.
- The general purpose controls are IP65 compliant.
- Most models are UL listed and CSA certified.