WHAT IS IT? The Model CMS-DSPO is a direct drive control that indicates when rotating equipment has ceased to turn. The output contacts of the Model CMS-DSPO can control up to two separate circuits, one for machinery shutdown and one for an alarm. A pulse output (12 pulses per revolution standard, 50 pulses per revolution optional with special disk) is also provided.
WHY IS IT NECESSARY? The Model CMS-DSPO provides a means of protection to prevent compound damage from inoperative or failed equipment due to a lack of rotation.
FEATURES? The Model CMS-DSPO differs from the standard model CMS as this unit has 2 separate relay outputs in addition to a pulse output.
Model | Description | Shipping Weight | |
---|---|---|---|
Lbs. |
Price US Funds |
||
CMS-1G-DSPO | Motion Control, Dual Setpoint & Pulse Output, 120 VAC, general purpose NEMA 4/4X | 7 | $ |
CMS-1X-DSPO | Motion Control, Dual Setpoint & Pulse Output, 120 VAC, explosion proof NEMA 7/9 | 7 | $ |
CMS-2G-DSPO | Motion Control, Dual Setpoint & Pulse Output, 240 VAC, general purpose NEMA 4/4X | 7 | $ |
CMS-2X-DSPO | Motion Control, Dual Setpoint & Pulse Output, 240 VAC, explosion proof NEMA 7/9 | 7 | $ |
CMS-3G-DSPO | Motion Control, Dual Setpoint & Pulse Output, 24V AC/DC, general purpose NEMA 4/4X | 7 | $ |
CMS-3X-DSPO | Motion Control, Dual Setpoint & Pulse Output, 24V AC/DC, explosion proof NEMA 7/9 | 7 | $ |
Epoxy coating option: add $ to price, add "E" to end of model number. | |||
For special 50 segment disk (and electronics), add "-50" to end of model number, and $ USD to price. For low RPM applications (5 RPM or less). | |||
Typical cardboard shipping carton measures 11" x 9" x 8" each. |
Note: Prices subject to change without notice.
Model | Description | Shipping Weight | |
---|---|---|---|
Lbs. |
Price US Funds |
||
CMS-10-DSPO | Model CMS-DSPO replacement electronic circuit board assembly, 120 VAC | 1 | $ |
CMS-20-DSPO | Model CMS-DSPO replacement electronic circuit board assembly, 240 VAC | 1 | $ |
CMS-30-DSPO | Model CMS-DSPO replacement electronic circuit board assembly, 24V AC/DC | 1 | $ |
20200009 | Replacement 12 segment brass encoder disk, standard. | 0.25 | $ |
20050179 | Replacement 50 segment brass encoder disk, for low speed applications (5 RPM or less). | 0.25 | $ | Typical cardboard shipping carton measures 11" x 9" x 8" each. |
Note: Prices subject to change without notice.
Part | Description | Shipping Weight | |
---|---|---|---|
Lbs. |
Price US Funds |
||
303 | Stub Shaft, 5/8" | 0.25 | $ |
304 | Flexible Coupling, 5/8" x 5/8" | 0.75 | $ |
305 | Coupling Guard | 0.5 | $ |
310 | Mounting Bracket | 2.0 | $ |
311 | Bearing Bracket (small), typically for pillow block bearings sized for 1-7/16" dia bore. | 3.5 | $ |
312 | Bearing Bracket (medium), typically for pillow block bearings sized for 1-15/16" to 2-7/16" dia bore. | 6.0 | $ |
313 | Bearing Bracket (large), typically for pillow block bearings sized for 2-15/16" to 3-15/16" dia bore. | 9.0 | $ |
CMS-K | CMS accessory mounting kit (includes 303, 304, 305, 310) | 4 | $ |
Note: Prices subject to change without notice.
- The housing is cast aluminum, with optional epoxy or polyester powder coatings available. These coatings will provide additional protection against corrosion.
- The unit can be connected to rotating equipment by means of a stub shaft and flexible coupling.
- The unit is mounted on the conveyor by drilling (4) 5/16" diameter holes. Mounting bolts are customer supplied.
- General purpose (weatherproof) units and explosionproof units have (2) 3/4" NPT conduit openings.
- The standard unit has 120 VAC power input (120 VAC transformer). Optional 240 VAC power input (240 VAC transformer) and 24V AC/DC (transformer-less) available upon request.
- The unit has two dry, unpowered DP/DT relays rated for 3A @ 120 VAC, 240 VAC, and 480 VAC.
- The unit is bi-directional, it will detect motion or loss of motion in either direction.
- The standard unit has a 12 segment brass encoder disk, yielding 12 pulses per revolution. A special 50 segment brass encoder disk (yielding 50 pulses per revolution) and electronics can be supplied for low RPM applications (5 RPM or less). Specify "-50" to end of model number.
- The maximum operating temperature is Class T6: 85°C [185°F].
- The maximum ambient temperature is 55°C [131°F].
- The general purpose units are rated NEMA Type 4/4X weatherproof and corrosion-resistant, and explosion proof units are rated NEMA Type 7/9 for vapor explosion proof and dust ignition proof (Class I, Div 1, Groups C & D; Class II, Div 1, Groups F & G).
- The general purpose controls are IP65 compliant.
- The model CMS-1G-DSPO and model CMS-1X-DSPO are cULus Certified. Other models are not currently agency listed.