Non-Contact Motion Control

Click image to enlarge
Model RMS

WHAT IS IT? The Model RMS is a non-contact motion control that indicates when a rotating shaft has slowed or quit moving altogether. The unit can be adjusted as an overspeed, underspeed, or zero speed control. The output contacts of the Model RMS can control up to two separate circuits, one for machinery shutdown and one for an alarm.

WHY IS IT NECESSARY? The Model RMS can shut down rotating equipment before damage is encountered. It provides protection for interlocked conveyor belts, especially if one of the belts fails due to overloading or tearing.

Models Available
Model Description Shipping Weight
  Lbs. Price
US Funds
RMS-1G Non-contact motion control, includes: 120 VAC electronics and NEMA 4,4X enclosure. 1.5 $277.00
RMS-2G Non-contact motion control, includes: 240 VAC electronics and NEMA 4,4X enclosure. 1.5 $277.00
RMS-3G Non-contact motion control, includes: 24V AC/DC electronics and NEMA 4,4X enclosure. 1.5 $277.00

Note: Prices subject to change without notice.

Accessories
Part Description Shipping Weight
  Lbs. Price
US Funds
RMS-8S 8 MM inductive proximity sensor 1 $423.00
RMS-12S 12 MM inductive proximity sensor 1 $175.00
RMS-18S 18 MM inductive proximity sensor 1 $180.00
RMS-30S 30 MM inductive proximity sensor 1 $187.00
RMS-8M 8 MM sensor mounting bracket 0.5 $12.00
RMS-12M 12 MM sensor mounting bracket 0.5 $12.00
RMS-18M 18 MM sensor mounting bracket 0.5 $12.00
RMS-30M 30 MM sensor mounting bracket 0.5 $16.00
RMS-C Two conductor cable (Belden 8442) 0.02 lbs./ft. $0.41 / ft.
RMS-T Target disk

(specify RMS-8T, -12T, -18T, or -30T)

1 $28.00

Note: Prices subject to change without notice.

Technical Specifications
  • The controller is available in a NEMA Type 4 (RMS-G) polycarbonate housing.
  • The controller is available in either a 120 VAC, 240 VAC, or 24V AC/DC power input. Specify input voltage upon ordering.
  • The sensor can be used in outdoor environments and is connected to the controller with a shielded twisted pair (Belden 8442).
  • The maximum separation distance between controller and sensor is 200 feet.
  • Each inductive sensor is supplied with 6 feet of electrical cable.  Field splice for longer lengths.
  • Input and output wiring done on external screw terminal strip.
  • The unit has a dry, unpowered DP/DT relay rated for 5A @ 120 VAC, 240 VAC, and 480 VAC.
  • Target disks available, or use any ferrous metal to generate pulses.
  • The operating temperature range is -50ºF to 150ºF (-45ºC to 66ºC).